© 2007-2010, IMI Cornelius Inc. - 22 - Publication Number: 621057403SER
NO CARBONATED WATER
Does the
carbonator pump start
when the unit is
turned on?
Check the carbonator pump
connection to the E-Board in the E-
Box.
No
Is the
incoming water
restricted?
Yes
Restore the
recommended water flow.
Yes
Is there
power connection to
the carbonator
pump?
No
1. Check whether or not there is
power across the carbonator power
cord on the E-Board in the E-Box..
2. Change carbonator power cord on
the E-Board in the E-Box.
No
Is the
pump motor
running?
Replace carbonator
pump.
Yes
No
1. Replace Carbonator
pump.
2. Check Y fitting on the
total flex manifold.
Yes
Comentarios a estos manuales