IDC 2XX Service Manual
Publication Number: 621057403SER - 17 - © 2007-2010, IMI Cornelius Inc.
Slushy ice or water in
hopper
Blocked drains in cold plate
Remove access covers in cold plate cover &
inspect/clean drains
Poor ice quality due to water quality or ice
maker problems
Correct water quality or repair ice maker
Beverage does not
dispense
No 24VAC to valves Restore 24 VAC to valves
No CO
2
pressure Restore CO
2
pressure
Beverage is too sweet Valve brix requires adjustment Adjust valve brix
Carbonator is not operating Repair carbonator
No CO
2
in carbonator Restore CO
2
pressure in carbonator
City water pressure supply low or inconsistent
Booster pump must be used if dynamic water
pressure drops below 40 psig.
Unit will not dispense
carbonated drinks.
Dispenses syrup only.
CO
2
pressure in carbonator tank is too high.
Check CO
2
pressure regulator setting. 75 psig
recommended. Relieve pressure from
carbonator tank.
Water valve will not open
Check electrical connection to water valve.
Check resistance of coil (should be 9 ohms).
Check for voltage at coil when brand button is
depressed.
Unit will not dispense
carbonated drinks.
Spurts CO
2
and syrup
only.
Carbonator tank is empty, because tank was
emptied while power was applied to unit. 5
minute time-out of carbonator pump/motor
occurred, and carbonator pump is locked off.
Unplug the unit and reconnect the unit. Main
control board will reset, ice agitation will occur,
and carbonator tank will refill to normal level.
Note that this can occur while the water filter
system is serviced or water supply is shutoff. If
drinks are drawn from the dispenser while
water pressure is shutoff, the carbonator pump
starts and runs continuously, then shuts off on
the 5 minute timeout.
1) low water pressure switch deactivates
carbonator pump, 2) after 5 minutes reset and
retry carbonator pump. If water supply is
restored, the 5 minute timeout will not occur.
Repeat reset a second time, but on a third
time, then lockout carbonator pump, which will
generate a service call.
Carbonated drinks are
flat (low on carbonation)
CO
2
is out Replace CO
2
Carbonator tank is 100% filled because the
city water pressure exceeds the carbonator
tank CO
2
pressure regulator setting.
CO
2
setting for the carbonator tank is 75 psig,
max water pressure is 60 psig. If necessary,
install a water pressure regulating valve.