DIAGNOSTICS GUIDE FOR THE MAIN CONTROL BOARD
State
Observed State of
Re
d LED
Sensor Input Control Response Service Remedy
0
Flash rate 3
seconds
Both probes read “wet”
Standby mode. Pump =
OF
F
No service required
1
Flash rate
1/2 second
Pump is OFF and HIGH
probe reads “dry” and LOW
probe reads “wet”
Waiting for level to drop
below LOW probe. Pump =
OFF
No service required
2
Flash rate
1/2 second
Both HIGH and LOW probes
read “
dry”
Normal mode.
Pump = ON
No service required
3
Flash rate
1/2 second
Entered when HIGH probe
do
es not detect liquid, and
LOW probe does detect
liquid, and pump is ON
Normal mode.
Pump = ON
No service required
4
Flash rate 1
second
Entered when HIGH probe
re
ads “wet” and LOW probe
reads “dry”
THIS IS AN ERROR
CONDITION.
- Check electrical
connections at the
carbonator tank, and at
connector J4 on the main
control board
- Black wire should be
connected to the LOW probe
and also to Pin 4 of
Connector J4
- Reverse the connections if
incorrect
- Replace harness if
necessary
5
ON continuously,
but “flickers” every
3 seconds
Poor signal connection to
the carbo
nator tank. May
result in short cycling of the
carbonator pump.
Able to continue to function
but carbonator pump short-
cycles. Pump will come on
each time a drink is drawn.
THIS SITUATION
SHOULD BE
CORRECTED.
Check the harness
connections of the red signal
wire at both ends:
1) at the carbonator ring
terminal and
2) at Pin 5 of the J4
connector at the main control
board
6 ON continuously
Entered when pump has run
con
tinuously for 5 minutes
THIS IS AN ERROR
CONDITION.
Unplug the unit and plug it
back in. This will reset the
unit's main control board and
restart the carbonator pump.