IDC 2XX Service Manual
Publication Number: 621057403SER - 13 - © 2007-2010, IMI Cornelius Inc.
CHANGE-OUT PROCEDURES
CARBONATED WATER/NON CARBONATED WATER CHANGE-OUT
1. Depressurize the system.
IMPORTANT: Both the syrup and water must
be
depressurized.
2. Push the valve lock down on the valve that
n
eeds the water type change and pull the valve
off the back block.
3. Remove the 4 screws holding the back block in
p
lace and remove the back block.
Remove
Screws
4. Pull the Y-fitting out by moving it from side to side until it releases.
5. Insert the Carbonated or Non-carbonated Y-fitting into the manifold.
NOTE:There is a tab on the top of the fittings to assist in proper installation.
Tab
Tab
6. Replace the back block and screw it in place.
7. Place the valve on the back block and lock in place.
8. Repeat for remaining valves, if necessary.
9. Reinstate pressure to syrup and water systems.
10. Proceed with valve set up.