IDC 2XX Service Manual
Publication Number: 621057403SER - 11 - © 2007-2010, IMI Cornelius Inc.
9. Allow sanitizer to remain in lines for fifteen (15) minutes.
10. Repeat the step above, applying a different product tube each time until all tubes are filled with the
sanitizing solution.
11. Remove the nozzle and syrup diffuser and clean them in a mild soap solution.
Rinse with clean water and reassemble the nozzle and syrup diffuser on the valve.
12. Rinse the parts in clean water, reassemble the valve and reconnect it to the dispenser.
13. Discard the tank of sanitizing solution and reconnect the product syrup tanks. Operate the valves until
all sanitizer has been flushed from the system and only product syrup is flowing.
Sanitize syrup lines, B–I–B Systems
1. Remove all the quick disconnects from all the B–I–B containers.
2. Fill a suitable pail or bucket with soap solution.
3. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water.
4. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
5. Rinse the B–I–B disconnects in the sanitizing solution.
6. Sanitizing fittings must be attached to each B–I–B disconnect. If these fittings are not available, the
fittings from empty B–I–B bags can be cut from the bags and used. These fittings open the
disconnect so the sanitizing solution can be drawn through the disconnect.
7. Place all the B–I–B disconnects into the pail of sanitizing solution. Operate all the valves until the
sanitizing solution is flowing from the valve. Allow sanitizer to remain in lines for fifteen (15) minutes.
8. Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution. Rinse with
clean water and reassemble the nozzle and syrup diffuser to the valve.
9. Remove the sanitizing fittings from the B–I–B disconnects and connect the disconnects to the
appropriate
B–I–B container. Operate the valves until all sanitizer has been flushed from the system and syrup is
flowing freely.
Replenishing CO
2
Supply (As Required)
NOTE:When indicator on the 1800-psi gage is in the shaded (“change CO
2
cylinder”) portion of the dial,
CO
2
cylinder is almost empty and should be changed.
1. Fully close (clockwise) the CO
2
cylinder valve.
2. Slowly loosen the CO
2
regulator assembly coupling nut allowing CO
2
pressure to escape, then remove the
regulator assembly from the empty CO
2
cylinder
.
3. Unfasten safety chain and remove the empty CO
2
cylinder.
!
WARNING:
To avoid personnel injury and/or property damage, always secure the CO
2
cylinder with a safety chain to
prevent it from falling over. Should the valve become accidently damaged or broken off, a CO
2
regulator can
cause serious personnel injury or death could occur.
4. Position the full CO
2
cylinder and secure with a safety chain.
5. Make sure gasket is in place inside the CO
2
regulator assembly coupling nut, then install the regulator
assembly on the CO
2
cylinder.
6. Open (counterclockwise) the CO
2
cylinder valve slightly to allow the lines to slowly fill with gas, then open
the valve fully to back-seat the valve (back-seating the valve prevents gas leakage around the valve shaft).
Check CO
2
connections for leaks. Tighten any loose connections.