  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
23 630460003
Trouble RemedyProbable Cause
UNIT OFF OR TRIPS CIRCUIT
BREAKER.
A. Ice jams up in evaporator
shell.
A. Clean inside surface of
evaporator shell.
B. Bin thermostat will not shutoff
machine. Set too cold.
B. Check and adjust or replace .
C. Auger motor has worn
bearings.
C. Check and replace.
D. Ice chute out of alignment,
restricted ice flow out of
evaporator section.
D. Realign.
E. Ice chute restricting ice flow. E. Align or replace ice chute if
damaged.
F. Incoming water temperature
too cold.
F. Maintain temperature above 50°F.
G. Bin thermostat does not
shutoff when bin is full of ice.
G. Adjust or replace bin thermostat if
necessary.
H. Mineral or scale deposits on
inside of evaporator shell and
evaporator.
H. Inspect and clean.
I. Low ambient temperature in
room where unit is located.
I. Maintain temperature above 50°.
J. Gearmotor sticking which
causes it to draw excessive
amperage.
J. Check and replace.
UNIT GOES OFF OR TRIPS
CIRCUIT BREAKER. (CONTD)
K. Plugged expansion valve
causing low back pressure.
K. Replace the drier-filter, evacuate
and recharge the system.
L. Refrigerant leak causing low
back pressure.
L. Find and repair leak. Replace the
drier-filter, evacuate and recharge
the system
M. Auger out of line. M. Check extruder bearing and
exchange as needed.
N. Broken auger N. Replace auger.
O. Low water level in float tank
reservoir.
O. Adjust float arm to maintain
correct water level.
P. Gearmotor Delay Thermostat
does not keep gearmotor
running after Bin Thermostat
opens.
P. Check operation and / or replace.