9 630460003
WATER AND ICE CIRCUIT
The supply water enters the float chamber through a small orifice. The water level rises and lifts the float arm on
the float valve and seats the valve, shutting off the water supply when the water is at the desired level. As the
water leaves the float chamber, filling the evaporator, the float drops and allows additional water to enter refilling
the float chamber. Thus the water level is maintained automatically as the unit operates.
The water level in the evaporator shell will rise to the same level as the water in the float chamber. The water in
direct contact with the evaporator wall freezes and forms ice on the evaporator wall. As the freezing continues
the ice becomes thicker and exceeds the space between the evaporator wall and the auger. The auger rotating
at 8 RPM then chips off the ice and moves it to the surface of the shell. When the ice reaches the top surface of
the water in the shell it is pushed upward through the extruder opening into the cutter heads. From the cutter
head the ice enters the drop chute and falls into the storage bin. This action continues until the ice comes in
contact with the bin thermostat and the unit is shut down. The unit will remain off until the ice drops from the bin
thermostat through consumption or melting, at which time the unit will restart.
Water Level
Water Inlet Fitting
Water Pressure Switch
Strainer
Gear Motor
Float Valve
Water Dump Valve
Evaporator
FIGURE 4. WATER LEVEL