Wilshire Juice Training Manual
- 18 - © 1999, IMI Cornelius Inc.
Pouch in holder wrong (flow restriction)
Low brix
False refill light
Decrease water flow
Might correct brix
False refill light
Poorly mixed drink
Pulsing/splashing dispense
Unmixed concentrate at bottom of cup
Pump slide not fully engaged
Low brix
False refill light
Decrease water flow
Cant achieve good brix
False refill light
Poorly mixed drink
Sticky pump rollers
Low brix
Decrease water flow
Cant achieve good brix
False refill light
Poorly mixed drink
Ambient water to dispenser
Drinks above 45°F during peak volume
Exceeds drink capacity of 20 oz. per
minute
Service call / complaint
NOTE: Must supply 3/8 chilled water
line to dispenser to generate
unlimited drink capacity.
1/4 water line to dispenser
Poor flow rate
High velocity dispense
Decrease water flow
Might correct brix
Poorly mixed drink
High velocity dispense
Pulsing/splashing dispense
Unmixed concentrate at bottom of cup
TROUBLESHOOTING QLT DRINK QUALITY PROBLEMS