Wilshire Juice Training Manual
© 1999, IMI Cornelius Inc. - 11 -
4.4 Miscellaneous Mechanical:
SLJs can be converted to QLTs (see IMI Cornelius QLT Training video).
There is one motor per concentrate pump. DC motors are used to allow vari-
able speeds. Some juice dispensers have speed switches which change the
motor voltage from 28 to 18. This slows the motor to accommodate very low
water pressure. This is especially useful when high concentrate ratios are used.
7. If necessary, remove and replace flow
control and check valve components.
8. Rebuild the valve and reassemble. Replace all O-rings making sure they are not
pinched or twisted. Be sure the cam-lock washers are in the grooves of the water
lines.
NOTE: O-rings should be lubricated with sanitary lubricant.
Check Valve
SYSTEM DETAILS