SERVICE AND MAINTENANCE
This section describes the service and maintenance procedures to be performed on the Unit.
IMPORTANT: Only qualified Personnel should service the Unit internal components or electrical wiring.
WARNING: Disconnect electrical power from the Unit to prevent personnel injury before
attempting any internal maintenance. Only qualified personnel should service the internal
components or electrical wiring.
PREPARING UNIT FOR SHIPPING, RELOCATING, OR STORING
CAUTION: Before shipping, relocating, or storing the Unit, the beer cooling coils must be
sanitized, all sanitizing solution must be purged from the beer coils, the ice bank must be
melted, and all water must be drained from the water tank. A freezing ambient environment
will cause residual water remaining inside the Unit to freeze resulting in damage to internal
components of the Unit.
PERIODIC INSPECTION
1. Check Unit condenser coil (see Figure 5) for accumulation of dust, lint, or grease and if necessary, clean
the coil as instructed. Restriction of air flow through the condenser coil will decrease cooling efficiency of
the Unit.
2. Check area in front, back, sides, and above the Unit for obstructions. These areas must be kept clear at all
times. Listed below are the minimum clearances that must be maintained.
A. Clearance above the Unit ––––––––––––––––––––––––––––– 12 inches to nearest obstruction.
B. Clearance back of Unit ––––––––––––––––––––––––––––––– 12 inches to nearest obstruction.
C. Clearance on sides of Unit –––––––––––––––––––––––––––––12 inches to nearest obstruction.
D. Clearance on front of Unit ––––––––––––––––––––––––––––– Open
3. Check beer faucets for dripping that indicates leaking and repair as necessary.
ADJUSTMENTS
ADJUSTING CO
2
REGULATORS
(see Figure 2)
NOTE: To readjust CO
2
regulator to a lower setting, loosen adjusting screw lock nut, then turn screw to
the left (counterclockwise) until pressure gage reads 5-psi lower than new setting will be. Turn adjust-
ing screw to the right (clockwise) until gage registers new setting, then tighten lock nut.
Adjusting Primary CO
2
Regulator.
Adjust primary CO
2
regulator by loosening regulator adjusting screw lock nut, then turn adjusting screw to the
right (clockwise) until gage registers 50-psi. Tighten adjustment screw lock nut after adjustment has been com-
pleted.