Cornelius I Series Especificaciones Pagina 49

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 48
TP00952
November 26, 200144
b. Insert measured drop (D) into formula and multiply by 6.6 to get a calculated drop (See
Figure 26).
example: A condenser located 8 ft. [2.438 meters] below the ice machine has a 52.8 ft.
[16.093 meters] calculated total (8 ft. x 6.6 = 52.8 ft.).
D
H
AIR
FLOW
COMBINATION OF
DROP(S)
WITH HORIZONTAL
FIGURE 26
c. Insert measured horizontal distance into formula. No calculation is necessary. (6 ft.) [1.828
meters].
d. Add the calculated rise, calculated drop, and horizontal distance together to get the total
calculated distance (25.5 + 52.8 + 6) equals 84.3 ft. [25.694 meters]. If 100 ft. [30.48 me-
ters] total calculated distance is exceeded, the condenser must be moved to a new loca-
tion which permits proper equipment operation (See Figure 27).
R
H
D
AIR
FLOW
COMBINATION OF RISE AND
DROP(S)WITH HORIZONTAL
FIGURE 27
CAUTION: If a line-set rise is followed by a line-set drop, a second line-set rise cannot
be made. Or If a line-set drop is followed by a line-set rise, a second line-set drop
cannot be made.
3. Lengthening or Reducing the Line-Set Lengths
In most cases, by routing the line-set properly, shortening will not be necessary (refer to illustration).
However, when shortening or lengthening is required, do so before connecting the line-set to the ice
machine or the remote condenser. This prevents the loss of refrigerant from the ice machine or the
condenser.
The quick connect fittings on the line-sets are equipped with Schrader Valves. Use these valves to
recover any vapor charge from the line-set. When lengthening or shortening lines, apply good refrig-
eration practices and insulate new tubing. Do not change the tube sizes. Evacuate the lines and
place approximately 5 oz. of vapor refrigerant charge in each line (See Figure 28).
Intermediate
Seal
Parent
Metal
Seal
SCHRADER
VALVE
FIGURE 28
Vista de pagina 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54

Comentarios a estos manuales