COMPONENT FUNCTION (CIRCUIT BOARD, ETC.)
SENSORS
Condenser sensor (WHITE) is a thermistor rated at 2618 ohms to 3032 ohms at 32_F (0_C).
Condenser sensor signals the circuit board for fan cycling and also serves as the high temperature safety
shut down. The red “DELAY LED” will flash on and off every second, during high temperature safety
delay. The yellow “ERROR LED” will flash on and off every second, during high temperature safety error.
Product is functionally shut down. Reset procedure must be performed to restart product operation.
RESET OPERATION
When Cuber is functionally shut down and red “Error LED” is operational, the Cuber power switch must
be turned off for 5 seconds and returned to the ON position to reset the circuit board and allow the Cuber
to restart operation.
Evaporator Switches
Proximity Switches are mounted to the evaporator, and the magnet is mounted to the side rail.
Switch Notes:
1. Manually holding the curtain open during freeze mode will shut the Cuber down in 5 seconds.
2. During harvest cycle, if curtain is open for 5 seconds, the water pump and the compressor will stop.
When the water curtain is closed, the Cuber will begin the normal start up process.
3. In single evaporator machines, the proximity switch connection must be on the top (RH) connection
on the circuit board.
4. In dual evaporator machines, both RH and LH switches must open and reset to start the next freeze
mode.
VOLTAGE CHECKS
Evaporator Proximity Switch Pins and Condenser Thermistor Pins
Turn Cuber power switch OFF. Disconnect proximity switch plug(s) and condenser sensor plug from the
circuit board. Use a digital multimeter set for D.C. Voltage; turn power switch ON, connect leads of meter
across the top two terminal pins on the board, (for the switch being tested), meter should read 5VDC ±
0.2 output voltage. If not, replace the circuit board.
STACKING CABLE
When stacking the Xtreme Ice Machine the connecting cable (connecting the two (2) circuit boards) will
allow: the bottom Unit to shut off on the full bin signal (or any error code), the top Unit will then finish the
cycle it is in and shut down. The Xtreme Ice Machine should never be stacked more than two high.
SENSOR [THERMISTOR] DIAGNOSIS
Condenser sensor – Turn Cuber power switch OFF. Disconnect sensor plug from board. Install test
lead part no. 164984009 and use digital multimeter set for D.C. Voltage. Turn power switch ON. Con-
nect the leads of the meter across the two leads of the test lead being checked. The meter should read 5
VDC ± 0.25 output voltage from the board. If voltage is not correct, replace the circuit board.
Should the cuber operation indicate there may be a fault in the sensor [thermistor] or the control board
circuit proceed as follows:
1. Condenser Sensor (white leads) - self-contained air-cooled only - water cooled and remote systems
use a resistor plug on the control board.
2. Shorted sensor – a steady low millivolt reading will be recorded. The reading will not change.
3. Open sensor – the multimeter will record control board output voltage of 5.0 VDC.
4. Should sensor (thermistor) pass the voltage test proceed to the control board diagnosis for LED se-