SPECIFICATION CHART
Models Condensing
Unit
VAC Hz Ph Comp
RLA
Fan
Amps
Grmtr
Amps
Refrigerant
Oz. Type
Circuit
Fuse
IMD300–15A Air Cooled 115 60 1 6 0.82 2 12 R134a 15
IMD302–15A Air Cooled 220/240 50 1 3 0.5 1.6 12 R134a 15
IMD300–30A Air Cooled 115 60 1 10.1 1 2 28 R404A 20
IMD300–30W Water Cooled 115 60 1 10.1 N/A 2 13 R404A 20
IMD301–30A Air Cooled 208/230 60 1 5.7 1 1.6 28 R404A 20
IMD301–30W Water Cooled 208/230 60 1 5.7 N/A 1.6 13 R404A 20
IMD302–30A Air Cooled 220/240 50 1 5.3 0.5 1.6 28 R404A 20
IMD302–30W Water Cooled 220/240 50 1 5.3 N/A 1.6 13 R404A 20
IMD600–30A Air Cooled 115 60 1 12 1 2 28 R404A 20
IMD600–30W Water Cooled 115 60 1 12 N/A 2 14 R404A 20
IMD601–30A Air Cooled 208/230 60 1 7.7 1 1.6 28 R404A 20
IMD601–30W Water Cooled 208/230 60 1 7.7 N/A 1.6 14 R404A 20
IMD602–30W Water Cooled 220/240 50 1 8.2 N/A 1.6 14 R404A 20
IMD600–90A Air Cooled 115 60 1 12 1 2 24 R404A 20
IMD600–90W Water Cooled 115 60 1 12 N/A 2 14 R404A 20
IMD601–90A Air Cooled 208/230 60 1 7.7 1 1.6 24 R404A 20
IMD601–90W Water Cooled 208/230 60 1 7.7 N/A 1.6 14 R404A 20
IMD602–90A Air Cooled 220/240 50 1 8.2 0.5 1.6 24 R404A 20
IMD602–90W Water Cooled 220/240 50 1 8.2 N/A 1.6 14 R404A 20
NOTE: FOR UNITS NOT LISTED IN ABOVE CHART, REFER TO NAMEPLATE OR CONTACT FACTORY