The operating positions of the switch are fixed, no adjustments are necessary. If switch replacement becomes
necessary, simply disconnect cable at connector, remove wires from switch.
TEMPERATURE / PRESSURE CHARTS*
Air Temperature
$10 lbs. Discharge Pressure
Water Temperature
50_
60_
70_
80_
90_
100_
40_ 65_ 90_ 40_ 65_ 90_
162
188
214
245
275
309
166
192
218
249
279
313
168
194
220
251
281
315
174
202
230
265
300
328
177
205
233
269
304
334
180
208
236
272
307
340
40_ 65_
80
92
114
124
161
187
85
97
120
120
167
193
90
102
124
147
171
195
90_
IMD300–5 & IMD300–15 IMD300–30
IMD600–30, IMD600–90
NOTE: The thermostatic expansion valve is non–adjustable on all models.
REFRIGERATION SYSTEM ADJUSTMENTS
A complete understanding of the icemaker and hermetic refrigeration system is necessary before any adjust-
ments are made. The refrigeration technician must use high and low side pressure readings, water and air tem-
peratures, plus general conditions of cleanliness to assess the refrigeration system status when making any
adjustments.
All icemaker products are tested and adjusted at the factory prior to shipment where the ambient temperature
ranges from 65_F to 90_F, depending on the season of the year.
Whenever a new icemaker is initially installed and started–up, it is imperative that the start–up operator make
the following checks and readjustments for local conditions.
EXPANSION VALVE
You will find a thermal expansion valve on ice makers, which is used to control the amount of refrigerant flowing
through the evaporator. Improperly installed or defective expansion valves may cause low production, soft ice,
squeaking from evaporator and excessive load inside evaporator.
By using general refrigeration trouble shooting along with the pressure charts, you can easily determine whether
or not the expansion valve is working properly.
ADJUSTMENT AND TROUBLESHOOTING
When troubleshooting the expansion valve, you must;
1. Be sure you have adequate water flowing into the evaporator, a clean and properly ventilated condenser,
and the system is properly charged and free of any restrictions. Also be sure compressor is operating prop-
erly.
2. Take reservoir water temperature and air temperature from condenser inlet and determine at what pressure
unit should be running. On machines equipped with thermostatic valve there is NO adjustment. If correct
pressure cannot be obtained, be sure system has time to stabilize, 10–15 minutes.
3. Be sure sensing bulb is located at outlet side of evaporator about 3–4 inches away from evaporator and be
sure to insulate well and clamp tightly to tubing. If system pressures are still not adequate, take a second
water and air temperature reading and go over other parts of the system for possible problems. If proper
charge is questionable evacuate and recharge to nameplate and leak check. If valve still malfunctions re-
place valve.