Low Water Safety Control – Adjust magnet by bending magnet arm as shown in figure 1 to shut down unit if
the water level drops below the line on the side of the reservoir.
Bin Control – Remove four screws from top of bin cover and lift cover so bin control plate can be manually lifted
until unit shuts down. Release plate and unit will restart (On IMD300–30, IMD600–30 and IMD600–90 the dis-
pense button must be depressed for 45 seconds before unit will start). Replace screws.
Dispense Switch and Mechanism – By depressing the dispense switch, the dispense mechanism door on the
storage bin will open, and chain, sprockets, and agitator will rotate counterclockwise.
NOTE: If any of these checks or adjustments cannot be achieved, refer to Troubleshooting Section of this
manual or call our technical support center for assistance at 1–800–238–3600.