Publication Number: 630460150 - 4 - © 2000-2014, Cornelius Inc.
SPECIFICATION CHART
Models
Condensing
Un
it
VAC HZ PH Wire
Comp.
RLA
Fan
Amps
GRMTR
Amps
Refrigerant Circuit
Fus
e
Oz. Type
UCR701--A Air Cooled 208/230 60 1 2 7.7 1.6 2 13 R404A 20
UCR701--W Water Cooled 208/230 60 1 2 7.7 N/A 2 13 R404A 20
Water Supply--Water inlet fitting is 1/4--inch SAE flare located at the top front of the Unit. The Unit is designed to operate on
water pressure between 10 PSI and 90 PSI.
Drain Overflow Line (Located at rear of the Unit) 3/8--inch Flexible Tubing
Ambient Operating Temperature 40° F to 100° F
Electrical:
Unit Electrical Rating 208/230 VAC, 60 Hz,11.3 Amps,
Single Phase
Recommended Electrical Supply 208/230 VAC, 60 hz, 20 Amps
Dedicated 3--Wire
Grounded Circuit
Table 1. Design Data
Unit Model Number:
(cont’d)