INITIAL START UP, CHECKS AND ADJUSTMENT INSTRUCTIONS
NOTE: Do not start Icemaker before completing installation steps on pages 6 and 7.
Turn on water supply (if Icemaker is water cooled turn water on to condenser also) turn on main power switch
(
located on top of electrical box), and make the following system checks:
NOTE: If Icemaker will not start be sure water reservoir is full. Low water safety control must be
pr
operly adjusted to start and shut down the Icemaker. If water level drops below bottom of reser-
voir, the Icemaker must shut down. Adjustment is
made by moving magnet up or down.
Water Level—If
necessary adjust float by bending float arm up or down as needed, push float assembly down until
Icemaker stops running. Release float and Icemaker will restart. Keep water in reservoir at level line while the
Icemaker is in operation. (See Figure 3)
Low Water Safety Control—Adju
st magnet by bending magnet arm as needed to shut unit down if water level
drops below bottom of reservoir.
Bin Control—Place ice ar
ound probe, unit should shut down in one minute. Remove ice from around probe, unit
should start in two minutes.
NOTE: For altitudes over 1000 feet above sea level, adjust range screw (behind end cover). Half
t
urn max. raises setting 4°F approx.
Figure 3. Icemaker Float Assembly
Water modulating valve (water cooled units only)—Ope
ning point of condenser water modulating valve should
be set to maintain proper operating pressure in the refrigeration system high side. (see chart on page 11). Closing
point of valve should be set low enough to close valve during compressor stand by periods. To raise, turn
counterclockwise, to lower turn clockwise.