Continuous Flow Icemaker Service Manual
© 2004-2014, Cornelius Inc. - 3 - Publication Number: 630460174SER
GENERAL INFORMATION
GENERAL DESCRIPTION
This section gives the Unit description, theory of operation, and design data for continuous flow icemaker series
500, 700, 1000, and 2000.
SPECIFICATION CHART
NOTE: For units not listed in above chart, refer to nameplate or contact factory service
Models
Condensing
Unit
VAC HZ PH Wire
Comp.
RLA
Fan
Amps
GRMTR
Amps
Refrigerant
Circuit
Fuse
Oz. Type
WCC500-A Air Cooled 115 60 1 2 10.5 1.1 2 20 R404A 20
WCC500-W Water Cooled 115 60 1 2 10.5 N/A 2 9 R404A 20
WCC502-A Air Cooled 220/240 50 1 2 5.3 0.5 1.6 24 R404A 20
WCC502-W Water Cooled 220/240 50 1 2 5.3 N/A 1.6 11 R404A 20
WCF510-A Air Cooled 115 60 1 2 10.5 1.1 2 20 R404A 20
WCF510-W Water Cooled 115 60 1 2 10.1 N/A 2 11 R404A 20
WCF512-W Water Cooled 220/240 50 1 2 5.3 N/A 1.6 11 R404A 20
WCC700-A Air Cooled 115 60 1 2 14.6 1.6 2 17.5 R404A 20
WCC700-W Water Cooled 115 60 1 2 14.6 N/A 2 11 R404A 20
WCC701-A Air Cooled 208/230 60 1 2 7.7 1.6 2 24 R404A 20
WCC701-W Water Cooled 208/230 60 1 2 7.7 N/A 2 13 R404A 20
WCC702-A Air Cooled 220/240 50 1 2 9.4 0.5 1.6 20 R404A 20
WCC702-W Water Cooled 220/240 50 1 2 8.2 N/A 1.6 13 R404A 20
WCF710-A Air Cooled 115 60 1 2 14.6 1.6 2 17.5 R404A 20
WCF710-W Water Cooled 115 60 1 2 12 N/A 2 13 R404A 20
WCC711-A Air Cooled 208/230 60 1 2 7.7 1.6 2 24 R404A 20
WCC711-W Water Cooled 208/230 60 1 2 7.7 N/A 2 13 R404A 20
WCF712-A Air Cooled 220/240 50 1 2 8.2 0.5 1.6 24 R404A 20
WCF712-W Water Cooled 220/240 50 1 2 8.2 N/A 1.6 13 R404A 20
WCC1001-A Air Cooled 208/230 60 1 2 10 1.5 2.1 22 R404A 30
WCC1001-W Water Cooled 208/230 60 1 2 7.5 N/A 2 17 R404A 20
WCC1002-A Air Cooled 220/240 50 1 2 8.9 0.85 2 26 R404A 20
WCF1101-A Air Cooled 208/230 60 1 2 10 1.5 2.1 22 R404A 30
WCF1101-W Water Cooled 208/230 60 1 2 7.5 N/A 2 17 R404A 20
WCF1102-A Air Cooled 220/240 50 1 2 8.9 0.85 2 26 R404A 20
WCC1001-R Remote 220/240 60 1 2 7.5 N/A 2 120 R404A 15
WCF1101-R Remote 208/230 60 1 2 7.5 N/A 2 120 R404A 15
WCC2001–A Air–Cooled 208/230 60 1 2 12.9 .85 (2) 2 46 R404A 25
WCC2001–R Remote 208/230 60 1 2 12.9 1.7 (2) 2 220 R404A 25
WCC2001–W Water Cooled 208/230 60 1 2 12.9 N/A (2) 2 28 R404A 25
WCC2002–A Air Cooled 220/240 50 1 2 11.4 .85 (2) 2 46 R404A 25
WCF2201–A Air–Cooled 208/230 60 1 2 12.9 .85 (2) 2 46 R404A 25
WCF2201–W Water Cooled 208/230 60 1 2 12.9 N/A (2) 2 28 R404A 25
WCF2202–A Air Cooled 220/240 50 1 2 11.4 .85 (2) 2 46 R404A 25
Comentarios a estos manuales