Cornelius 1000-Series Manual de servicio Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
Continuous Flow Icemaker Service Manual
© 2004-2014, Cornelius Inc. - 9 - Publication Number: 630460174SER
Quarterly
This is the maximum period of time between cleaning and sanitizing the icemaker. In addition to recommended
monthly procedure, and if a more frequent cleaning and sanitizing pattern has not been established, unit must be
cleaned and sanitized.
Semi-Annually
Semi–Annually in addition to all previously established service procedures perform the following:
REPLACE
OK
REPLACE
1/16
OK
1/16
1. Check for water leaks in tube connections, water fittings and lower icemaker water seal.
2. Check drain tubes for clogs and aged tubes. Replace if tubes are stained or brittle.
3. Check for signs of condensation. Clean where necessary and replace insulation properly.
4. Check safety circuits for proper operation.
5. Check refrigeration system.
6. Check unit for abnormal noise. Tighten machine and cabinet screws, if necessary.
7. Check white upper bearings on auger assembly. If bearings are less than 1/16 thick, replace.
Figure 5. Upper Nut and Bearing Assembly