630460146
7
October 27, 2003
ELECTRICAL
1. All wiring and connections must conform to national and local electrical codes.
2. Wire size and circuit protection must conform to specifications and cuber must be on a separate electrical
circuit.
3. Strain relief connectors must be used at the junctions box of the control box and the cuber.
4. Cuber must be grounded by the control box ground screw or other method for intentional safety grounding
that meets code requirements.
5. A manual disconnect in a convenient location to the cuber must be installed.
NOTE: See Remote Install Instructions, page #30.
NOTE: All HP-62 (R404A) ice machines have a voltage range of –5%, +10% from the serial plate rating.
INSTALLATION CHECK POINTS
1. Has bin and cuber been leveled and sanitized?
2. Does electrical and plumbing meet code requirements?
3. If water-cooled, are inlet and drain connections to condenser correct to prevent “water hammer”?
4. Are drain lines separate and vented?
5. Is there 6I clearance on all sides and top for proper air circulation?
6. Does the water curtain move freely, and does the inlet solenoid valve shut off incoming water to the
water pan?
7. Has the unit been properly sealed to the bin or dispenser?
NOTE: A 6” top clearance will improve service accessibility.
START UP SEQUENCE
1. Check all connections.
2. Turn on the main power switch, the red LED will flash (6) times then be on steady for (4) seconds.
3. The unit will go through a 45 second hot gas defrost to remove any ice on the evaporator.
NOTE: If there is a very large slab of ice on the evaporator you will need to push the manual harvest
button to remove it.
4. If the water pan is empty, the unit will go through a fill cycle.
5. There will be approximately a (45) second evaporator pre chill, then the water pump will start, and the
freeze cycle begins.
PREVENTATIVE MAINTENANCE SEQUENCE
The installation is not complete until you are sure the owner–operator understands the cuber operation and his
or her responsibility of preventative maintenance.
Does the owner–operator know:
1. Location of electrical disconnect switch and water shut–off valves?
2. How to start and/or shut down the product, clean and sanitize it?
3. Bin full operation and reset operation of high pressure cutout (water–cooled and remote products
only)?
4. How to clean the condenser and fan blade?
5. Whom to call for product information and/or service?
NOTE: CONDENSER SENSOR USED ONLY ON A/C UNITS. 1.8K ohm RESISTER USED ONLY ON W/C
& R/C UNITS.