Cornelius Xtreme 330 Series Especificaciones Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
630460146
6
October 27, 2003
DISPENSER INSTALLATION
1. The proper cuber/dispenser installation package should be ordered. This package will include gasket mate-
rial, and hold-down bracket, and bin stat.
2. RTV applications (See Fig. 2 above). If the ice bin is full, new ice will not be able to drop. Instead it blocks
the evaporator curtain open and no additional ice is made. This new ice may start to melt and the resulting
liquid can leak out of the joint between the ice maker and bin. To prevent this problem, seal the joint with
food grade silicon sealant.
3. Install bin thermostat (Part Number 631500074).
AIR-COOLED MODELS
WATER-COOLED MODELS
Electrical Service Line
Manual Disconnect
Switch
STRAIN RELIEF
MUST BE USED
Water Filter
Shut-Off Valve
Dump
Valve
Drain
Tube
Bin Drain
Tube
*Air Gap 4”
“minimum”
Electrical Service Line
Manual Disconnect Switch
Shut-Off Valve
Water Filter
Shut-Off Valve
Condenser Water Inlet
Dump Valve
Drain Tube
*Air Gap 4”
“minimum”
Bin Drain
Tube
Condenser Water
Drain Tube
Strain Relief
must be used
Note: Leave all panels on the cuber until it is in place on the bin.
* An air gap of at least twice the diameter of the water supply inlet plus a minimum of 1” (25 mm) must
exist between the floor drain and drain tube.
Floor Drain
Floor Drain
FIG. 4 FIG. 5
PLUMBING CONNECTIONS
1. All plumbing lines and connections must conform to local and
national plumbing codes.
2. Line shut-off valves must be located in supply water lines for cuber and condenser if product is water-
cooled. Water supply to water-cooled condenser must include a stand-pipe to prevent “water
hammer”.
3. Should your local water supply quality require the installation of a water filter system, consult your local dis-
tributor or dealer for proper size required.
4. Water supply pressure must not be lower than 20 PSI (1.37 BAR), nor should it exceed 70 PSI (8.16 BAR).
NOTE: Water filters larger then 5 microns do not give proper protection. Water pressures above 70
PSI (5.44 BAR) will destroy the filter.
DRAIN LINES: Bin and cuber drain lines must never be connected together and must be vented.
NOTE: Always flush inlet water lines 1–2 minutes before connecting to Ice Maker.
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 25 26

Comentarios a estos manuales

Sin comentarios