UC100 Operator’s Manual
© 2008, IMI Cornelius Inc. - 7 - Publication Number: 621054211OPR
MONTHLY
Clean and sanitize the hopper interior and auger assembly.
Cleaning Interior Surfaces
CAUTION: When pouring liquids into the hopper, do not exceed the rate of 1/2 gallon per
minute.
IMPORTANT: Perform the following at least once a month.
1. Open right hand hopper cover, then remove all ice from hopper.
2. Lift up and remove the left hand hopper cover.
3. Remove agitator disk and agitator assembly.
10. Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior of the hopper
and the agitator assembly. Go to the lower auger drive area and also spray with sanitizing solution.
Allow to air dry.
11. Using the spray bottle filled with sanitizing solution, spray the inside of the two halves of the auger
tube, the auger, the two halves of the chute assembly and the undersides of the right and left
covers. Allow to air dry.
12. Reassemble the two halves of the auger tube and place back into its mounting. The longer tube
must be placed in front. Holding the auger by the upper shaft end, insert it into the guide tube.
NOTE: The bottom of the auger has a depression in the shape of a D. When replacing the auger,
it will be necessary to rotate the auger after insertion in the tube to engage the motor shaft. Make
certain that the auger slips into it drive pin. Auger transition cap will not assemble properly if the
auger is not seated on its drive pin.
13. Replace the auger transition cap onto the auger and lock down by snapping the retaining bail onto
the auger transition cap. Reinstall the tower cover.
14. Reinstall the covers. Put the right cover on first before you close the left cover.
4. Remove tower cover.
5. Move the retaining bail to the rear of the
tower which will allow removal of the auger
transition cap.
6. Grasp the ice auger by the shaft end and
lift out the auger tube. Take care not to
damage either end of the auger. The tube
will separate into two halves for easy
cleaning when fully removed.
7. Remove the front panel of the cabinet
below the hopper, this will give you access
to the lower auger drive area and the
passage between the hopper and the
auger for cleaning.
8. Using the previously prepared soap
solution to clean the hopper covers,
agitator disk, and agitator assembly,
interior of the hopper, both halves of the
ice chute, auger, auger tubes, and the
lower auger area of the auger housing.
Thoroughly rinse all parts with potable
water. Spray all components with
sanitizing solution and allow to air dry.
9. Reassemble the agitator assembly and
disc into the hopper. Make certain that the
retaining screw is tight.
AUGER TRANSITION CAP
AUGER TUBE BACK
AUGER TUBE FRONT
AUGER
RETAINING BAIL