IDC 255 Progate Drive Thru Service Manual
Publication Number: 621057419SER - 22 - © 2006, IMI Cornelius Inc.
TROUBLESHOOTING
POWER LIGHT OFF
POWER LIGHT OFF
Is the unit plugged
into a socket
No
1. Plug unit into a socket.
1. Check the external power supply
breakers.
2. Open the e box and check that the
power cord wires (black and white) are
connected to the e - board.
3. Check the connector between control
box and the e box.
Are there other
equipments on the
same circuit
Yes
No
Yes
1. Remove all other equipment
from the machine circuit.
2. Install a new dedicated circuit
for the machine.