13 166240010
WINTER STORAGE
If the unit is to be stored in an area where the temperature will drop below freezing, it is most important that all
water lines be drained to prevent them from freezing and possible rupture.
To blow out the water line, disconnect the water supply at the cabinet inlet and use air pressure to force the wa-
ter into the water reservoir pan. This can then be removed from the water pan.
WATER COOLED CONDENSER
– To remove water from condenser unhook water supply and attach com-
pressed air hose. Start machine. As head pressure reaches the appropriate level opening the water regulating
valve, the compressed air will force the water out. Do not let the machine operate longer than necessary.
CLEANING THE CONDENSER (AIR COOLED)
In order to produce at full capacity, the refrigeration condenser must be kept clean. The frequency of cleaning
will be determined by surrounding condition. A good maintenance plan calls for an inspection at least every two
months.
Remove the unit compartment grill at the front. With a vacuum cleaner, remove all accumulated dust and lint
that has adhered to the finned condenser.
CAUTION: CONDENSER COOLING FINS ARE SHARP. USE CARE WHEN CLEANING.