59 TD 204
Trouble RemedyProbable Cause
CUBER NOT
OPERATING
INDICATOR
LIGHTS OFF,
POWER TO
THE CIRCUIT
BOARD
A. Magnet not
in proximity
switch field.
A. Water curtain
drifting out of
switch range.
Reduce
clearance
between curtain
and proximity
switch.
B. No curtain
movement.
B. Adjust proximity
switch.
C. Faulty
proximity
switch.
C. Replace
proximity switch.
D. Unit OFF
due to bin
full.
D. Remove ice from
curtain.
Eliminate curtain
restriction.
COMPRESSOR
DOES NOT
RUN, CIRCUIT
BOARD
INDICATOR
LIGHTS ON
A. Check
contactor
and leads.
A. Replace if
defective.
B. Compressor
overload
open.
B. Permit overload
to cool and reset
or replace.
C. Check
compressor
and start
components.
C. Replace as
needed.