Cornelius I Series Manual de servicio Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
13 TD 204
Should a different thickness of the bridge be desired, it will be re-
quired to adjust the ice thickness POT, located on the circuit
board, as follows:
1. Thinner Bridge turn the ice thickness pot adjust-
ment screw CW one full turn. Allow two cycles
before determining if additional adjustments are re-
quired.
2. Thicker Bridge turn the ice thickness pot adjusting
screw CCW one full turn. Allow two cycles before
determining if additional adjustments are required.
NOTE: Never judge the thickness of the ice from the first
batch of the ice produced the first cycle is a bal-
ance cycle. Always wait for the second cycle before
making any adjustments.
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 65 66

Comentarios a estos manuales

Sin comentarios