I-Series Ice Machine Training Manual
- 22 -
© 2001, IMI Cornelius Inc.
3. RED & YELLOW BOARD DIAGNOSTICS
With ice machine in freeze cycle, push and hold the Hot Gas Manual Harvest/Defrost But-
ton until circuit board goes into diagnostic mode (about 3 seconds). The ice machine starts
to cycle these five components:
1. Hot Gas Solenoid
2. Water Pump
3. Contactor
4. Fan Motor
5. Dump Valve.
Check to make sure the proximity switch lights are on.
When replacing the circuit board make sure the dip switches are set correctly.
One Curtain Switch Must Be
115V
#7 YL Water Pump
#7 YL Water Pump
#6 BK Condenser Fan
#5 BL P.S.
#4 BL
#3 RD Hot Gas
#2 WH L2
#1 BR L1
#7 YL Water Pump
#6 BK Condenser Fan
#5 BL P.S.
#4 BL
#3 RD Hot Gas
#2 RD L2
#1 BR L1
the second can be connected J5
SW4-1 OFF
SW4-2 ON
SW4-3 ON
230V
SERVICE