Xtreme Ice Training Manual
TP00952
October 17, 2005
10
CLEANING PROCEDURES
Approved ice machine cleaners by brand names:
S Calgon Nickel Safe (green color only)
NOTE: Failure to use approved products will void the warranty.
CAUTION: Ice machine cleaners are acidic-based chemicals. Before beginning any
cleaning of the cuber, the ice in the storage bin or dispenser must be removed.
WARNING: When using any chemical, rubber gloves and eye protection should be worn.
Cleaning Procedure if there is ice on the evaporator plate.
1. Turn the power switch on.
2. Press and hold the Harvest button to start a 4 minute defrost cycle. (Button is located on the control
board see Figure 5).
FILL VALVE
WATER PRESSURE LINE
POWER
NEUTRAL
HOT GAS
WATER PUMP
COMPRESSOR
FAN MOTOR (AIR COOLED)
DUPM VALVE
RH EVAP
SWITCH
LH EVAP
SWITCH
STOCKING
CABLE PLUG
NOTE: CONDENSER SENSOR USED ONLY ON A/C UNITS.
1.8K ohm RESISTER USED ONLY ON W/C AND R/C UNITS.
(WHITE LEAD)
CONDENSER SENSOR SEE NOTE
(BLACK LEAD)
WATER TEMP SENSOR
ERROR
DELAY
CLEAN
HARVEST
UNIT
SELECTION
SWITCH
S3–1
BIN
SWITCHES
TRANSFORMER
#1
#3
#2
#4
#5
#6
#7
BRIDGE
THICKNESS
POT
S3–2
OFF
3 2 1
OFF
ON
ON
MICRO
PROCESSOR
(MANUFACTURING DATE)
3643001
FIGURE 5
NOTE: Condenser sensor used only on A/C units. 1.8k resistor used only in W/C and R/C units.
Single evaporator units must have the proximity connected in the top connection.