Managing the Bowl Levels
When one of the two level probes (SLIVx) fails to detect the presence of liquid in the bowl, the EVCARx
is enabled to restore the correct level.
The probes relating to each bowl are completely independent, therefore the following situation will occur:
FIGURE 34
FIGURE 35
NOTE 1: The level/s refill phase must take place within a maximum time lapse which is controlled by the
(controller (see Alarms chapter).
NOTE 2: The level/s refill phase may only concern one of the two bowls, but it will maintain the same
features.
NOTE 3: It is essential that the safety probes are covered for the bowl/s filling phase to take place.
Safety Probes (only for ICE FROST GENERIC Pre-mix)
In addition to the two level probes relating to the two bowls (see FIGURE 32 through FIGURE 35), the
µZ4LP system also monitors the two safety probes designed to monitor the presence of liquid in the
external tanks.
The monitoring of the condition of the safety probes (covered/uncovered) is only active during the bowl
loading phase. It follows, then, that a lack of liquid in the tanks during the non-loading phases will not be
signalled.
If: SSIC1 KO when EVCAR 1 = OFF - no signal
SSIC2 KO when EVCAR 2 = OFF - no signal
Example of how the safety system works:
Supposing the safety probe SSIC 1 is uncovered and the solenoid valve EVCAR 1 is de-energized. In
this case there will be no signal.
Then the level probe SLIV 1 located in the bowl 1 is uncovered. The solenoid valve EVCAR 1 is enabled
to allow the bowl 1 to fill up correctly.