CLASSIC 1000
REMOTE COOLER
2
2. AIR COOLED MODEL
INSTALLATION INSTRUCTIONS
2.1 SITING
2.2 SITING & INSTALLATION DIAGRAM
Remote
Cellar
Ensure Unit is
mounted on a level
surface
Unit requires
adequate ventilation
Chilled
Cellar
SIDE VIEW
Install on
firm level
surface
100mm (minimum) clearance
required to allow adequate ventilation
2.0m max
PLAN
13A Socket
Castors allow
movement in
any direction
1. Do not drag over rough floors or down steps and
always keep in an upright position.
2. Site as near to the stored product as possible.
3. Avoid siting in a chilled cellar, unless cellar cooling
is uprated by 1.5kw
4. Allow access to side and front panels, for
maintenance and servicing.
5. Avoid siting the unit in warm areas with poor
ventilation (i.e. cupboards or small storerooms).
6. Prevent exposure to water spillage, spray or very
high humidity.
7. Never allow air vents (louvres) to become
obstructed or blocked.
8. Protect from physical damage and do not place
heavy items on top.
9. Locate the Classic 1000 within 2m of a grounded,
switched, 13 amp, 230V socket which is easily
accessible for isolation of the cooler.
The socket should be installed to current IEE
regulations. It is recommended that the mains
electrical supply is protected by RCCB.
The Cooler must be earthed.
10. The cooler is designed to operate in the range of
ambient temperatures from 10°C up to 35°C.