23
630460154
TROUBLESHOOTING CHART -- ICEMAKER NOT OPERATING
NO POWER
Check electrical wiring in con-
trol box for loose connec-
tions.
Check for fai led service
switch or relay.
Check power to machi ne.
ICEMAKER RUNS BUT
DOES NOT MAKE ICE
Condenser fan running
but compressor not running
Check li ne voltage.
Check compress or winding
& components.
LOW WATER SAFETY
SWITCH OPEN
Remote c ondenser
not running.
Evaporator water tube
may have an air bubble.
Clear air bubble from
tube.
Check power
to condenser.
Check electrical
wiring in control box
for loose connections .
High pressure
switch open or
cyclingonandoff.
Check that water is turned on.
Check for restric tion in water line.
Check inc oming water pressure
(minimum 10 lbs.).
Check water safety switch.
ICEMAKER OPERATING BUT
SOFT ICE
Check bin switch
Clean all related
drain lines.
Refer to guide
to Good Ice in
servic e manual .
GEARMOTOR OVERLOAD
TRIPPED
Check water l evel control
and evaporator water tube
for lime build up restriction.
CAUTION
Clear ice from
evaporator and
auger before re-
setting over-
load.
CLEAN
see
instructions.
Reset
overload.
Icemaker runs
Reset but
motor does
not run.
Will not
reset.
Overload
hot try
again.
Will not
reset
replace
overload
Check
gearmotor
circuit.
Short run trips
again in 2 mi n-
utes. Check gear-
motor circuit.
IMPORTANT
Icemaker runs when reset
but problem has not been
found.
Continue check ing for
overload as follows to
guard against future
problems
Low suction pressure
(20 lbs. or below).
TXV bulb
lost charge.
Replace valve
evacuate and
recharge.
High suction pressure
(30 lbs. or above).
Suction line
not
insulated.
Bulb
uninsul ated.
Clean and
insulate.
TXV not
operating
properly.
Bulb
loose.
Clean
and
tighten.
Head
Pressure
high.
Valve
stuck
open.
Replace
valve.
Condenser
dirty or
restricted.
Condenser
fan not
running.
To o m uc h
refrigerant in
system.
Non-condensible
in system.
Discharge
king valve
partially
clos ed.
Open
valve
Evac uate and
recharge system.
Clean condenser.
Check electrical circuit
to fan motor.
Check fan motor.
Low press ure switch open
orcyclingonandoff.
Low on
refrigerant.
Plugged
liquid line
dryer.
Restricted
liquid line.
Plugged or
faulty TXV.
Icemaker
froze up.
Check if
auger is
turning.
Replace
valve.
Evac uate
and
recharge
system.
Check for
kinks or
damage to
liquid line.
Replace
dryer.
Evac uate
and
recharge
system.
LAC not operating
properly (minimum
disc harge pressure
180 lbs.).
Check for
leaks.
Replace LAC valv e,
evacuate and
recharge system.
Check drive on
gearmotor.
Check gears in
gearbox.
Check if extruding
head is down i n
evaporator tube.
OVERLOAD GUIDE
ELECTRICAL
High or low voltage weak power lines can caus e ov erloads on icemaker restarts
High running c urrent. Check motor c ircuits and start relay -- Auger delay failed.
ICEMAKER
Mechanic al parts worn. S cored evaporator or auger. Worn thrust bearing.
Ice maker not turning off. Failed ice level control.
Over compress ion. Low water i nlet temperature. Res triction in water line from
reservoir.
REFRIGERANT
Contaminated charge or bad compressor.
Low c harge or gas leak.
Low suction pressure. Improper expansi on valve sensing bulb. Loc ation or insulation
and/or defective expansi on v alve
No
Remote c ondenser
units only
Remote c ondenser
units only
No
Yes
Yes No
Comentarios a estos manuales