UC 150 Ice Dispenser Operator’s Manual
© 1999-2014, Cornelius Inc. - 9 - Publication Number: 620917311
CLEANING AND SANITIZING INSTRUCTIONS
Soap solution - Use a mixture of mild detergent and warm (100° F) potable water.
Sanitizing solution - Use 1/2 ounce of household bleach in 1 gallon of potable water. Preparing the sanitizing
solution to this ratio will create a solution of 200 PPM.
DISPENSER
1. CLEANING EXTERIOR SURFACES
IMPORTANT: Perform the following daily.
1. Remove the cup rest from drip tray.
2. Wash the drip tray with soap solution. Rinse with potable water and allow solution to run down the drain.
3. Wash cup rest with soap solution and rinse in potable water. Install the cup rest into the drip tray.
4. Clean all exterior surfaces with soap solution and rinse with potable water.
2. CLEANING INTERIOR SURFACES
When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per minute.
IMPORTANT: Perform the following at least once a month.
1. Open right hand hopper cover, then remove all ice from hopper.
2. Lift up and remove the left hand hopper cover.
3. Remove agitator disk and agitator assembly.
4. Remove tower cover by removing three thumb screws.
5. Move the retaining bail to the rear of the tower which will allow removal of the ice chute assembly.
6. Grasp the ice auger by the shaft end and lift out the auger tube. Take care not to damage either end of
the auger.
7. Remove the auger tube by lifting upward. The tube will separate into two halves for easy cleaning when
fully removed.
8. Open the front door of the cabinet below the hopper, this will give you access to the lower auger drive
area and the passage between the hopper and the auger for cleaning.
9. Using the previously prepared detergent solution clean the hopper covers, agitator disk, and agitator
assembly, interior of the hopper, both halves of the ice chute, auger, auger tubes, and the lower auger
area of the auger housing. Thoroughly rinse all of the previously cleaned with potable water.
10. Reassemble the agitator assembly and disc into the hopper. Make certain that the retaining screw is
tight.
11. Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior of the hopper and
the agitator assembly. Go to the lower auger drive area and also spray with sanitizing solution. Allow to
air dry.
12. Using the spray bottle, spray the inside of the two halves of the auger tube, the auger, the two halves of
the chute assembly and the undersides of the right and left covers. Allow to air dry.
13. Reassemble the two halves of the auger tube and place back into its mounting. Holding the auger by
the upper shaft end, insert into the guide tube. Make certain that the auger slips into it drive pin. Chute
assembly will not assemble properly if the auger is not seated on its drive pin. Reassemble the upper
auger and chute assembly onto the auger and lock down by snapping the bail onto the upper housing.
Reinstall the tower cover with the thumb screws.
14. Reinstall the covers. Put the right cover on first before you close the left cover.
Comentarios a estos manuales