Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com ©2013 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.
©2013 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com
DIFFERENTIAL PRESSURE
DIMENSIONS (5-Valve Manifold Assembly)
Model 230
Wet-to-Wet Pressure Transducer
ORDERING INFORMATION
Table 1. Range Specication
RANGE
CODE
UNIDIRECTIONAL RANGE
CODE
BIDIRECTIONAL
PSID PSID
001PD
002PD
005PD
010PD
025PD
030PD
050PD
100PD
0 to 1.0
0 to 2.0
0 to 5.0
0 to 10.0
0 to 25.0
0 to 30.0
0 to 50.0
0 to 100.0
0R5PB
001PB
2R5PB
005PB
010PB
025PB
050PB
±0.5
±1.0
±2.5
±5.0
±10.0
±25.0
±50.0
Model Range Code Pressure Fitting Output Bleed Screw Seals Optional
2301 = 230 See Table 1 Below 2F 1/4” NPT (F) 11 4-20 mA Std. B Viton/Silicone C Calibra-
tion
Certicate
3V 3-Valve Manifold* 2D 0-5 VDC Opt. A Buna-N
5V 5-Valve Manifold* 2E 0-10VDC
2 3 0 1
*Order assembled with the Model 230 (Code 3V or 5V) or separately as Option 891. (Manifold can only be mated with Setra's Model 230.)
Please contact factory for
versions not shown.
4,00
102
7.05
179
5.63
179
3.25
83
0.38
10
0.156
4
0.31
8
5.80
143
7.83
199
2.33
59
Note: V6 and V7 bleed valves are not required when used with a Setra
Model 230. Use the bleed screws on Model 230 to bleed the lines of air.
Low Process/Commission
1/4”NPT Connection
V6
V7
V4
V5
V1 V2
High Process Connection
1/4”NPT
Low Process Connection
1/4”NPT
V3
Model 230
Dierential Pressure Transducer
SHUT OFF VALVES
SHUNT VALVE
5-Valve Manifold Assembly
Description
(Order as Pressure Code Fitting “5V”.)
For dierential pressure measurements at high line pressure (350 psig max), it is
recommended that the pressure sensor be installed with a valve in each line, plus
a shunt valve across the high and low (reference) pressure ports as shown.
Ordering Example: 2301005PD2F11B = Model 230 0 to 5 psid unidirectional, 1/4-18 NPT Male tting, 4 to 20 mA Output, and Viton/Silicone Seals.
2301005PD3V11B = Model 230, 0 to 5 psid unidirectional, 3-Valve Manifold, 4 to 20 mA, Output, and Viton/Silicone Seals (Assembled w/3- Valve Manifold).
V1
V2
V3
V4 V5
SSP230 Rev. J 4/4/14